Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 132(15): 152501, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38683002

RESUMO

We report the first mass measurement of the proton-halo candidate ^{22}Al performed with the low energy beam ion trap facility's 9.4 T Penning trap mass spectrometer at facility for rare isotope beams. This measurement completes the mass information for the lightest remaining proton-dripline nucleus achievable with Penning traps. ^{22}Al has been the subject of recent interest regarding a possible halo structure from the observation of an exceptionally large isospin asymmetry [J. Lee et al., Large isospin asymmetry in Si22/O22 Mirror Gamow-Teller transitions reveals the halo structure of ^{22}Al, Phys. Rev. Lett. 125, 192503 (2020).PRLTAO0031-900710.1103/PhysRevLett.125.192503]. The measured mass excess value of ME=18 092.5(3) keV, corresponding to an exceptionally small proton separation energy of S_{p}=100.4(8) keV, is compatible with the suggested halo structure. Our result agrees well with predictions from sd-shell USD Hamiltonians. While USD Hamiltonians predict deformation in the ^{22}Al ground state with minimal 1s_{1/2} occupation in the proton shell, a particle-plus-rotor model in the continuum suggests that a proton halo could form at large quadrupole deformation. These results emphasize the need for a charge radius measurement to conclusively determine the halo nature.

2.
Rev Sci Instrum ; 94(10)2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37815423

RESUMO

At the ReAccelerator within the Facility for Rare Isotope Beams, a combination of an interchangeable aluminum foil and a silicon detector was developed to quantify isobaric contamination in rare isotope beams. The device is simple to operate and is now used routinely. In this article, we describe the system and show an application of the device to determine the level of contamination of an Si-32 rare isotope beam by stable S-32. In addition, we describe how the new diagnostic device helped confirm an enhancement of the beam purity prior to beam delivery to experiments.

3.
Rev Sci Instrum ; 93(1): 013306, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35104937

RESUMO

A challenge preventing successful inverse kinematics measurements with heavy nuclei that are not fully stripped is identifying and tagging the beam particles. For this purpose, the HEavy ISotope Tagger (HEIST) has been developed. HEIST utilizes two micro-channel plate timing detectors to measure the time-of-flight, a multi-sampling ion chamber to measure energy loss, and a high-purity germanium detector to identify isomer decays and calibrate the isotope identification system. HEIST has successfully identified 198Pb and other nearby nuclei at energies of about 75 MeV/A. In the experiment discussed, a typical cut containing 89% of all 198Pb80+ in the beam had a purity of 86%. We examine the issues of charge state contamination. The observed charge state populations of these ions are presented and, using an adjusted beam energy, are well described by the charge state model GLOBAL.

4.
Phys Rev Lett ; 126(15): 152701, 2021 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-33929230

RESUMO

The discrepancy between observations from γ-ray astronomy of the ^{60}Fe/^{26}Al γ-ray flux ratio and recent calculations is an unresolved puzzle in nuclear astrophysics. The stellar ß-decay rate of ^{59}Fe is one of the major nuclear uncertainties impeding us from a precise prediction. The important Gamow-Teller strengths from the low-lying states in ^{59}Fe to the ^{59}Co ground state are measured for the first time using the exclusive measurement of the ^{59}Co(t,^{3}He+γ)^{59}Fe charge-exchange reaction. The new stellar decay rate of ^{59}Fe is a factor of 3.5±1.1 larger than the currently adopted rate at T=1.2 GK. Stellar evolution calculations show that the ^{60}Fe production yield of an 18 solar mass star is decreased significantly by 40% when using the new rate. Our result eliminates one of the major nuclear uncertainties in the predicted yield of ^{60}Fe and alleviates the existing discrepancy of the ^{60}Fe/^{26}Al ratio.

5.
Phys Rev Lett ; 126(4): 042501, 2021 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-33576685

RESUMO

We report high-precision mass measurements of ^{50-55}Sc isotopes performed at the LEBIT facility at NSCL and at the TITAN facility at TRIUMF. Our results provide a substantial reduction of their uncertainties and indicate significant deviations, up to 0.7 MeV, from the previously recommended mass values for ^{53-55}Sc. The results of this work provide an important update to the description of emerging closed-shell phenomena at neutron numbers N=32 and N=34 above proton-magic Z=20. In particular, they finally enable a complete and precise characterization of the trends in ground state binding energies along the N=32 isotone, confirming that the empirical neutron shell gap energies peak at the doubly magic ^{52}Ca. Moreover, our data, combined with other recent measurements, do not support the existence of a closed neutron shell in ^{55}Sc at N=34. The results were compared to predictions from both ab initio and phenomenological nuclear theories, which all had success describing N=32 neutron shell gap energies but were highly disparate in the description of the N=34 isotone.

6.
Phys Rev Lett ; 123(23): 239905, 2019 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-31868474

RESUMO

This corrects the article DOI: 10.1103/PhysRevLett.120.032701.

7.
Phys Rev Lett ; 123(14): 142502, 2019 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-31702191

RESUMO

From detailed spectroscopy of ^{110}Cd and ^{112}Cd following the ß^{+}/electron-capture decay of ^{110,112}In and the ß^{-} decay of ^{112}Ag, very weak decay branches from nonyrast states are observed. The transition rates determined from the measured branching ratios and level lifetimes obtained with the Doppler-shift attenuation method following inelastic neutron scattering reveal collective enhancements that are suggestive of a series of rotational bands. In ^{110}Cd, a γ band built on the shape-coexisting intruder configuration is suggested. For ^{112}Cd, the 2^{+} and 3^{+} intruder γ-band members are suggested, the 0_{3}^{+} band is extended to spin 4^{+}, and the 0_{4}^{+} band is identified. The results are interpreted using beyond-mean-field calculations employing the symmetry conserving configuration mixing method with the Gogny D1S energy density functional and with the suggestion that the Cd isotopes exhibit multiple shape coexistence.

8.
Phys Rev Lett ; 120(3): 032701, 2018 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-29400535

RESUMO

We report the mass measurement of ^{56}Cu, using the LEBIT 9.4 T Penning trap mass spectrometer at the National Superconducting Cyclotron Laboratory at Michigan State University. The mass of ^{56}Cu is critical for constraining the reaction rates of the ^{55}Ni(p,γ) ^{56}Cu(p,γ) ^{57}Zn(ß^{+}) ^{57}Cu bypass around the ^{56}Ni waiting point. Previous recommended mass excess values have disagreed by several hundred keV. Our new value, ME=-38626.7(7.1) keV, is a factor of 30 more precise than the extrapolated value suggested in the 2012 atomic mass evaluation [Chin. Phys. C 36, 1603 (2012)CPCHCQ1674-113710.1088/1674-1137/36/12/003], and more than a factor of 12 more precise than values calculated using local mass extrapolations, while agreeing with the newest 2016 atomic mass evaluation value [Chin. Phys. C 41, 030003 (2017)CPCHCQ1674-113710.1088/1674-1137/41/3/030003]. The new experimental average, using our new mass and the value from AME2016, is used to calculate the astrophysical ^{55}Ni(p,γ) and ^{56}Cu(p,γ) forward and reverse rates and perform reaction network calculations of the rp process. These show that the rp-process flow redirects around the ^{56}Ni waiting point through the ^{55}Ni(p,γ) route, allowing it to proceed to higher masses more quickly and resulting in a reduction in ashes around this waiting point and an enhancement to higher-mass ashes.

9.
Phys Rev Lett ; 117(25): 252501, 2016 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-28036225

RESUMO

Bunched-beam collinear laser spectroscopy is performed on neutron deficient ^{52,53}Fe prepared through in-flight separation followed by a gas stopping. This novel scheme is a major step to reach nuclides far from the stability line in laser spectroscopy. Differential mean-square charge radii δ⟨r^{2}⟩ of ^{52,53}Fe are determined relative to stable ^{56}Fe as δ⟨r^{2}⟩^{56,52}=-0.034(13) fm^{2} and δ⟨r^{2}⟩^{56,53}=-0.218(13) fm^{2}, respectively, from the isotope shift of atomic hyperfine structures. The multiconfiguration Dirac-Fock method is used to calculate atomic factors to deduce δ⟨r^{2}⟩. The values of δ⟨r^{2}⟩ exhibit a minimum at the N=28 neutron shell closure. The nuclear density functional theory with Fayans and Skyrme energy density functionals is used to interpret the data. The trend of δ⟨r^{2}⟩ along the Fe isotopic chain results from an interplay between single-particle shell structure, pairing, and polarization effects and provides important data for understanding the intricate trend in the δ⟨r^{2}⟩ of closed-shell Ca isotopes.

10.
Phys Rev Lett ; 116(1): 012501, 2016 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-26799013

RESUMO

We report the determination of the Q(EC) value of the mirror transition of (11)C by measuring the atomic masses of (11)C and (11)B using Penning trap mass spectrometry. More than an order of magnitude improvement in precision is achieved as compared to the 2012 Atomic Mass Evaluation (Ame2012) [Chin. Phys. C 36, 1603 (2012)]. This leads to a factor of 3 improvement in the calculated Ft value. Using the new value, Q(EC)=1981.690(61) keV, the uncertainty on Ft is no longer dominated by the uncertainty on the Q(EC) value. Based on this measurement, we provide an updated estimate of the Gamow-Teller to Fermi mixing ratio and standard model values of the correlation coefficients.

11.
Phys Rev Lett ; 114(23): 232502, 2015 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-26196795

RESUMO

We report the first direct measurement of the (14)O superallowed Fermi ß-decay QEC value, the last of the so-called "traditional nine" superallowed Fermi ß decays to be measured with Penning trap mass spectrometry. (14)O, along with the other low-Z superallowed ß emitter, (10)C, is crucial for setting limits on the existence of possible scalar currents. The new ground state QEC value, 5144.364(25) keV, when combined with the energy of the 0(+) daughter state, Ex(0(+))=2312.798(11) keV [F. Ajzenberg-Selove, Nucl. Phys. A523, 1 (1991)], provides a new determination of the superallowed ß-decay QEC value, QEC(sa)=2831.566(28) keV, with an order of magnitude improvement in precision, and a similar improvement to the calculated statistical rate function f. This is used to calculate an improved Ft value of 3073.8(2.8) s.

12.
Phys Rev Lett ; 113(23): 232502, 2014 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-25526121

RESUMO

A novel technique has been developed, which will open exciting new opportunities for studying the very neutron-rich nuclei involved in the r process. As a proof of principle, the γ spectra from the ß decay of ^{76}Ga have been measured with the SuN detector at the National Superconducting Cyclotron Laboratory. The nuclear level density and γ-ray strength function are extracted and used as input to Hauser-Feshbach calculations. The present technique is shown to strongly constrain the ^{75}Ge(n,γ)^{76}Ge cross section and reaction rate.

13.
Rev Sci Instrum ; 85(9): 093503, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25273722

RESUMO

A new data acquisition system including a Field Programmable Gate Array (FPGA) based time-resolved scaler was developed for laser-induced fluorescence and beam bunch coincidence measurements. The FPGA scaler was tested in a collinear laser-spectroscopy experiment on radioactive (37)K at the BEam COoler and LAser spectroscopy (BECOLA) facility at the National Superconducting Cyclotron Laboratory at Michigan State University. A 1.29 µs bunch width from the buncher and a bunch repetition rate of 2.5 Hz led to a background suppression factor of 3.1 × 10(5) in resonant photon detection measurements. The hyperfine structure of (37)K and its isotope shift relative to the stable (39)K were determined using 5 × 10(4) s(-1) (37)K ions injected into the BECOLA beam line. The obtained hyperfine coupling constants A((2)S(1/2)) = 120.3(1.4) MHz, A((2)P(1/2)) = 15.2(1.1) MHz, and A((2)P(3/2)) = 1.4(8) MHz, and the isotope shift δν(39, 37) = -264(3) MHz are consistent with the previously determined values, where available.

14.
Rev Sci Instrum ; 85(2): 02B701, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593600

RESUMO

An electron-beam ion trap (EBIT) charge breeder is being brought into operation at the National Superconducting Cyclotron Laboratory at Michigan State University. The EBIT is part of the ReA post-accelerator for reacceleration of rare isotopes, which are thermalized in a gas "stopping" cell after being produced at high energy by projectile fragmentation. The ReA EBIT has a distinctive design; it is characterized by a high-current electron gun and a two-field superconducting magnet to optimize the capture and charge-breeding efficiency of continuously injected singly charged ion beams. Following a brief overview of the reaccelerator system and the ReA EBIT, this paper presents the latest commissioning results, particularly, charge breeding and reacceleration of the highly charged rare isotopes, (76)Ga(24 +, 25 +).

15.
Phys Rev Lett ; 109(4): 042301, 2012 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-23006079

RESUMO

We report a precise determination of the (19)Ne half-life to be T(1/2)=17.262±0.007 s. This result disagrees with the most recent precision measurements and is important for placing bounds on predicted right-handed interactions that are absent in the current standard model. We are able to identify and disentangle two competing systematic effects that influence the accuracy of such measurements. Our findings prompt a reassessment of results from previous high-precision lifetime measurements that used similar equipment and methods.

16.
Phys Rev Lett ; 106(3): 032501, 2011 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-21405268

RESUMO

A high-precision half-life measurement for the superallowed ß+ emitter 26Al(m) was performed at the TRIUMF-ISAC radioactive ion beam facility yielding T 1/2 6346.54 ± 0.46(stat) ± 0.60 (syst) ms, consistent with, but 2.5 times more precise than, the previous world average. The 26Al(m) half-life and ft value, 3037.53(61) s, are now the most precisely determined for any superallowed ß decay. Combined with recent theoretical corrections for isospin-symmetry-breaking and radiative effects, the corrected Ft value for (26)Al(m), 3073.0(12) s, sets a new benchmark for the high-precision superallowed Fermi ß-decay studies used to test the conserved vector current hypothesis and determine the V(ud) element of the Cabibbo-Kobayashi-Maskawa quark mixing matrix.


Assuntos
Alumínio/química , Partículas beta , Radioisótopos/química , Meia-Vida
17.
Phys Rev Lett ; 102(13): 132501, 2009 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-19392349

RESUMO

High-precision Penning-trap mass measurements of the N approximately Z approximately 34 nuclides 68Se, 70Se, (70m)Br, and 71Br were performed, reaching experimental uncertainties of 0.5-15 keV. The new and improved mass data together with theoretical Coulomb displacement energies were used as input for rp process network calculations. An increase in the effective lifetime of the waiting point nucleus 68Se was found, and more precise information was obtained on the luminosity during a type I x-ray burst along with the final elemental abundances after the burst.

18.
Phys Rev Lett ; 96(15): 152501, 2006 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-16712152

RESUMO

The mass of the short-lived radio nuclide 38Ca (T(1/2) = 440 ms) has been measured with the 9.4-T Penning trap mass spectrometer of the Low-Energy Beam and Ion Trap Facility. A mass uncertainty of deltam = 280 eV has been achieved, corresponding to deltam/m = 8 x 10(-9). The result makes 38Ca, a superallowed beta emitter, a new candidate to test the conserved-vector-current hypothesis. The experiment is also the first demonstration that short-lived radioactive isotopes produced by projectile fragmentation of relativistic heavy-ion beams can be slowed down and prepared such that precision experiments of this kind are possible.

19.
Appl Radiat Isot ; 54(2): 365-9, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11200900

RESUMO

The specific radioactivity concentrations of 226Ra, 232Th and 40K have been determined by gamma ray spectrometry with an HPGe detector in clay brick samples from kiln sites located in 17 towns. The average values of the measured activities are 35, 72, and 585 Bq kg(-1), respectively, for the above radionuclides. The average estimated radium equivalent concentration is 183 Bq kg(-1) and is comparable with reported values for many countries in the world. This value and the value obtained from the criteria formula suggest that the use of local clay bricks do not pose a radiological hazard. The calculated average absorbed dose rate in air within buildings was found to be 102 nGy h(-1) while the population weighted indoor annual effective dose was 0.20 mSv.


Assuntos
Materiais de Construção , Raios gama/efeitos adversos , Poluentes Radioativos do Ar/efeitos adversos , Poluentes Radioativos do Ar/análise , Silicatos de Alumínio , Argila , Humanos , Radioisótopos de Potássio/efeitos adversos , Radioisótopos de Potássio/análise , Doses de Radiação , Rádio (Elemento)/efeitos adversos , Rádio (Elemento)/análise , Espectrometria gama , Sri Lanka , Tório/efeitos adversos , Tório/análise
20.
Biol Trace Elem Res ; 71-72: 189-94, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10676492

RESUMO

Air particulate matter of two size fractions (coarse [2.5-10 microns] and fine [less than 2.5 microns]) were collected at an urban residential site (Colombo University ground) over a period of 12 mo during 1996 using a Gent PM10 stacked filter unit. Seventy-five sets of samples collected during this period were analyzed for 10 elements: Al, Si, K, S, Ca, Ti, Fe, Zn, Br, and Pb by energy-dispersive X-ray fluorescence, which is a multielement analysis. This is a highly sensitive technique enabling quantitative analysis of very low masses. The average concentrations of lead, sulfur, and bromine, which are generally associated with combustion products of automotive exhausts, dominate the fine fraction in this study. The minimum and maximum concentration of lead resulting in an annual average of 0.09 microgram/m3 was found to be 0.0042 and 0.441 microgram/m3 in particulate matter with less than 10 microns equivalent aerodynamic diameter. The maximum concentration determined is well below the limits set by the World Health Organization (0.5-1.0 microgram/m3). The recommended value for Pb in Sri Lanka is 0.5 microgram/m3. Al, Si, Ca, Ti, and Fe exhibited enhanced concentrations in the coarse fraction, which probably originate from disturbed soil as a result of wind and traffic.


Assuntos
Poluentes Atmosféricos/análise , Poluentes Atmosféricos/química , Monitoramento Ambiental , Tamanho da Partícula , Espectrometria por Raios X , Sri Lanka
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...